Order #
Your order will be delivered on 23rd March 2016.
TO PROLONG THE LIFE OF YOUR SECTIONAL BUILDING, WE RECOMMEND YOU ADHERE TO THE FOLLOWING INFORMATION
Always check there are no overhanging branches or leaves above your building, this can wear away the felt or break off and damage the roof. Check you have no puddles of water collecting under your shed. All furniture must be oiled on a regular basis. Silicone seals around doors and windows may need to be replaced when required. Your sectional building is manufactured from 100% pressure treated timber, so your building is protected against rot and insect attack. If water penetration occurs we recommend you seal your building with a waterproof paint or sealant. We recommend Protek (royal exterior) which can be purchased direct from us. More than one coat may be required, check the manufacturers recommendations. Please allow adequate space around your building for future maintenance. Also gutters can be fitted, this stops drips of water being blown on to the building, and also stops splash back onto the bottom of the building. If your sectional building is erected in damp inclement conditions, you must ensure you leave adequate ventilation to allow the sectional building to dry. If you fail to ventilate the building whilst timbers are drying out, condensation will occur. This will produce drips or runs of water inside the building, which may be mistaken for leaks. Condensation will also build up on the inside of the windows. We use heavy duty felt, this is the best on the market because it is manufactured with tar and oil, It can move with atmospheric conditions, this is out of our control. We felt the buildings in a way that has been tried and tested by the company for over twenty years. Roof is always larger than building size.
Important Delivery Information of Panels
For shed floors which are 6 x 4, 7 x 5, 10 x 6, and 10 x 8, our floor bearers will run the long way, every 24". Your bearers must run the short way and always opposite to ours.
The perfect base is a concrete base which is completely flat and level, no raised or low areas. Alternatively, concrete paving slabs may be used, which must cover the whole area and be perfectly flat and level. The size of the base needs to be the size of the floor area, no smaller. The roof over hang will always be larger.
Please allow maintenance area around your building to waterproof your building. You may also need to add gutters - Any queries, please call as we are here to help.
When we deliver panels, some are:
Some are like this:
A free yellow sticker is provided to help the driver to locate your property, if your house is hard to find. Please telephone 01424 716716 , if you feel you should have one.
These panels must go around your property, not through it. If necessary and in order to accommodate, please remove fence panels or any obstructions (i.e. overhanging tree limbs, arches, wires or gutters etc.). If going through gates, there must be no arches, bars or lintels above.
Remember also, that these panels and roofs are extremely heavy! Normally there is only two people on each van. These personnel are employed to erect your building and not to rectify your base or access problems. If you have any worries, please call the office and we can arrange a free site visit.Drawings not to scale!